DB-5ms GC Columns
Agilent TechnologiesAgilent J&W DB-5ms features an excellent signal-to-noise ratio for analytical applications.
Environmental monitoring and testing assess the quality of our air, water, soil, and overall ecosystems. Using advanced technologies and analytical methods, environmental scientists collect and analyze samples to measure levels of pollutants, contaminants, and other factors impacting environmental health. By monitoring changes over time and identifying potential risks to human health, this field plays a vital role in informing policy decisions and implementing effective mitigation strategies. Explore how environmental monitoring and testing contribute to safeguarding our planet's well-being and promoting sustainable development.
Agilent J&W DB-5ms features an excellent signal-to-noise ratio for analytical applications.
Agilent J&W HP-5ms has very low bleed characteristics that are ideal for GC/MS. The column has excellent inertness for active compounds, including acidic and basic compounds, and improved signal-to-noise ratio for better sensitivity and mass spectral integrity.
Agilent J&W HP-FFAP is designed primarily for the analysis of organic acids, free fatty acids, or samples that require quantitation of acidic impurities. The FFAP stationary phase is modified with acid to provide a very inert column that can accommodate the demanding analysis of acids dissolved in water.
CP-Wax 52 CB GC columns have lower minimum temperature and a higher maximum temperature than non-bonded polyethylene glycol (PEG) columns due to extensive cross linking, delivering higher resolution of low-boiling-point analytes. With guaranteed reproducibility and excellent temperature stability, CP-Wax 52 CB is ideal for EPA and ASTM methods.
Agilent J&W CP-Sil 88 for Dioxins has a very high polarity and a specific selectivity for dioxin and dibenzofuran separations. The column is supplied with an integrated retention gap to avoid problems with solvent condensation, thus allowing repeated splitless injections without phase deterioration, extending column life.
Agilent J&W DB-624 is recommended for EPA methods 502.2 and 8021, as well as for fast GC/MS volatiles analysis. It is specifically designed for the analysis of volatile priority pollutants and residual solvents.
Introduce volatile compounds from virtually any sample matrix into your GC or GC/MS. Automatic Leak Check, Priority Sample Positions, and Barometric Pressure Compensation improve uptime and efficiency.
Dependable leak-free capillary connections allow reliable backflush, split flow, heart-cutting, and GC x GC on Agilent 8890 and 7890 GC systems. These devices are low thermal mass, oven mountable, and inert.
GC/MS methods are widely used for forensic toxicology, especially for the screening of large numbers of target compounds in complex matrices. Full-scan EI methods offer many advantages for broad-range screening, such as an unlimited number of targets, full-spectrum identity confirmation, and library searching for identification of non-targets. Technologies such as Capillary Flow Technology backflushing, Deconvolution Reporting…
Based on the Agilent 990 Micro GC, this Natural Gas Analyzer offers fast analyses with with easy-to-use software and the ability to calculate all required physical properties.
Purge and Trap (P&T) performs highly sensitive volatile organic compound (VOC) analysis with low carryover, allowing accurate and precise GC and GC/MS determination of VOCs in water, wastewater, soils, and sludges.
Based on the 7890 GC and 5977A Series Single Quadrupole Mass Spectrometer, the GC/MS PAH Analyzer is suitable for analyzing poly-cyclic aromatic hydrocarbons in environmental and food samples.
200A pore size; available in 2.0, 4.6, 10and 21.2 mm ids, and lengths from 50 - 250 mm. Pursuit columns are ideal for pharmaceutical applications using LC/MS, from analyzing lead compounds and biological samples in drug discovery, to implementing dependable analysis of raw materials and approved drugs in the QC process. Build on the large 200A pore size silica, high liquid density delivers up to 40% faster separations witho…
600 bar; superficially porous, 2.7 µm particle6; available in 2.1 - 4.6 mm id; 30 - 150 mm lengths. ZORBAX Eclipse Plus columns feature improved silica, special bonding and optimized endcapping that combine to deliver exceptional peak shapes for a wide range of analytes. Agilent's Poroshell 120 columns have a solid 1.7 µm core and a porous .5 µm outer layer, for a total 2.7 µm particle that delivers high resolution and high…
600 bar; superficially porous, 2.7 µm particle6; available in 2.1 - 4.6 mm id; 30 - 150 mm lengths. ZORBAX Eclipse Plus columns feature improved silica, special bonding and optimized endcapping that combine to deliver exceptional peak shapes for a wide range of analytes. Agilent's Poroshell 120 columns have a solid 1.7 µm core and a porous .5 µm outer layer, for a total 2.7 µm particle that delivers high resolution and high…
400 bar; available in 2.1 - 4.6 mm id; 30, 50, 75, 100, 150 mm lengths. Manufactured by Agilent to rigorous QC specifications, the ZORBAX family encompasses 5 particle sizes and more than 32 phases, for reliable scalability and transferability from HPLC to UHPLC, from lab to lab and around the world.
Extend-C18 columns incorporate a unique patented bidentate silane, combined with a double-endcapping process that protects the silica from dissolution at high pH - up to pH 11.5.
Experience the power of analytical compound isolation
The 1260 Infinity II LC System is a robust HPLC that offers the widest choice of modules for analytical HPLC and entry-level UHPLC, delivering the performance, reliability, and robustness you need for highest confidence in your daily results.
The 1260 Infinity II Bio-Inert Pump is a quaternary UHPLC pump that is made of bio-inert material for use in biological and extreme pH applications. This pump enables gradient formation and solvent blending from up to four solvents and operates at pressures up to 600 bar and flow rates up to 10 mL/min.
The 1290 Infinity II Diode Array Detector (DAD) delivers multiple wavelength detection with full spectra at sampling rates up to 240 Hz for ultrafast UHPLC separations. The Max-Light cartridge cell features optofluidic waveguides, which improve light transmission to near 100% efficiency without sacrificing resolution caused by cell dispersions effects.
The 1260 Infinity II Preparative Autosampler is designed for automated sample handling in routine purification applications. This flow-through vialsampler supports preparative flow rates of 200 mL/min and 600 bar pressure. Increase your daily throughput of purified sample by injecting up to 132 preparative samples with a maximum of 3.6 mL volume.
The 1260 Infinity II Quaternary Pump is a gradient pump that uses low-pressure mixing for UHPLC gradient formation and solvent blending from up to four solvents. This pump operates at pressures up to 600 bar and flow rates up to 10 mL/min.